Description
Reference: 1788070 EAN code:
Product name: Plastic Filter Rd40 A2B2P3
Maker: Honeywell Safety Products.
Protection type: Respiratory protection.
Product: Filter RD40
Type: A2B2P3. RD40.
Brand: Honeywell
Packaging: 1 unitWeight: 300 g
Characteristics:
– The A2B2P3 filter is part of the wide variety of plastic filters offered in order to protect against various organic gases / vapors with a boiling point above 65 ° C, inorganic gases and vapors and acids and vapor particles, solid and liquid.
– The Honeywell product range provides high quality and economical protection.
– For use with full face mask and half mask equipped with an Rd40 connector- Light and resistant plastic housing.
– Material: ABS. Activated and impregnated charcoal without chromium.
– Diameter 106 mm
Certifications:
EPI Category III.
ISO 9001/2000
Normas: EN 141, EN14387 y EN143.
Checks before use:
Users must:
– Make sure that the level of protection offered by the filter is sufficient for the type and concentration of the contaminant in the work area.
– Respect the expiration date that appears on the filter.
– Check the hermetic closing points.
Life cycle: It depends on the absorption capacity, the concentration of pollutants, the humidity and the respiration of the user.
Storage information:
-4 years after the date of manufacture
-6 months after opening- Store the filters in a cool, dry place with the caps on- The maximum allowed storage period is specified in the filter- Storage temperature range: -20 ° C / + 50 ° C
– Maximum humidity during storage: 80%
Limitations of use:
– For the exclusive use of trained and qualified personnel.
– Do not use if the oxygen level in the environment is less than 17%.
– After use, an open filter will be properly repackaged with its caps if it is likely to be reused. It must be replaced within 6 months after opening.
– If a user identifies the filter rupture through the smell or the knowledge of a gas, the filter must be replaced immediately.
– If the breathing resistance of the filter increased significantly, it must be replaced.
– Particular precautions to be taken in ATEX environments.
– Filter with a mass greater than 300 g cannot be used directly on half masks.